FOR ADVANCED TURBO:
Device provided with a permanent automatic pressure reducer, which works in the specified pressure range, according to the table (Pic 01). Do not remove this automatic pressure reducer – subject to warranty loss. |
FOR ALL MODELS:
On hotter days, this product allows a great saving of electricity and water. For this, turn the selector to a lower temperature setting and adjust the water flow with the shower tap.
ADVANCED FLEX: To get the most of your heating system, proceed as indicated at item 9 (usage and temperature control) and achieve maximum energy and water savings.
Read the table below, before request especialized or technical support.
PROBLEM | PROBABLY REASON | SOLUTION |
The product does not turn on automatically by opening the water valve. | The circuit breaker is turned off. | Turn on the circuit breaker. |
The temperature selector is in the OFF position. *** The thermal protector is activated. |
Set the temperature selector in a heating position. *** The product must be brought to an authorized technical service. |
|
No water coming out. | The main water valve is closed or there is air in the pipeline. | Open the main water valve and/or the taps in the same hydraulic circuit, to the air come out of it completely. |
Decreased water flow. | Dirt in the spreader. | Clean the spreader in order to unblock the water flow (item 11). |
The shower heats a little, even with the selector in the highest temperature position. | Inadequate wiring. | Consult a technician to check if the wiring conforms to the specifications described in this manual. |
Low electrical voltage. | Consult a technician to check if the voltage is below the nominal values (127V~ or 220V~). If positive, contact your regional electrical supply. | |
For Turbo models: The pressure is not increasing. | ||
The hydraulic installation working pressure may be higher than indicated for this product. | Check if the pressure is adequate, according to the specifications described in this manual. | |
The Residual Current Circuit Breaker (RCCB) is tripping off. |
Inadequate grounding system. | Adequate the grounding system. |
Electrical circuit shared with other products. | Provide na individual and exclusive electrical circuit for the shower. | |
Dripping after closing the shower tap. | Natural flow of the water stored inside the product after finished. | The shower should be in a parallel line to the floor. If it is not like this, align the product tiltment. |
Water leakage in the shower tap. | Fix the shower tap. | |
Dirt in the spreader, blocked holes. | Clean the spreader in order to unblock the holes (item 11). | |
IMPORTANT: If the heating element burns, replace it with another according to the model, voltage, and power of the shower. References: Advanced Multi and Advanced Multi Turbo: 3055-Q (127V~ 5500W), 3055-P (220V~ 6400W), 3055-O (220V~ 7500W); Advanced Electronic and Advanced Electronic Turbo: 3056-E (127V~ 5500W) and 3056-F (220V~ 7500W). For the Advanced Shielded model, if the shielded element burns, the product must be sent to an authorized technical service. In case of defects in the electrical wiring chord of the product, do not replace them. Remove the product from point of use and take it to an authorized technical service. ***Applicable for the shower Advanced Shielded only. |